Interfaz en español. Las fichas, los resúmenes y las fuentes conservan su idioma original.

Todos los avisosVulnerabilidad
Hablar con Oktsec
Barracuda

Email Security Gateway and affected software

CVE-2026-116606CVE-2026-111560Actualizado 11 nov 2026
Actuar ahoraAtaques confirmados

Seguí las novedades de seguridad

Alertas prioritarias y resúmenes de Radar por correo.

Aviso de seguridad

Barracuda confirms exploitation affecting a small number of organizations. ESG has both flaws; the command injection also affects other listed appliances, with different authentication requirements.

Quiénes deben revisar: Teams operating the Barracuda appliances listed in the affected systems table.

Acción recomendadaCorrección disponible

Restrict administration access to trusted networks, install the latest firmware and verify the applicable security patch. Investigate prior exposure separately from patching.

¿Cuál es la vulnerabilidad y su impacto?

CVE-2026-116606 bypasses authorization on ESG without credentials when the administrative interface is reachable. CVE-2026-111560 requires administrative access on its own. The combined ESG path can reach root; that chain must not be assumed for every listed product.

The vendor corrected the authentication description on November 5 and confirmed exploitation on November 9. CISA added both CVEs on November 10. These dates do not establish when attacks began.

Firmware and security patches are separate checks. Follow the product table rather than assuming the latest firmware alone completes remediation.

Proveedor / autor
Barracuda
Identificadores de vulnerabilidad
CVE-2026-116606 · CVE-2026-111560
Acceso necesario
Depende de la aplicación o configuración
Divulgado
2 nov 2026
Última revisión de evidencia
11 nov 2026 UTC

¿Qué sistemas y versiones están afectados?

ProductoAfectadoVersión corregida / acción
Email Security Gateway (both CVEs)Appliances missing the applicable security patch; administration UI must be reachable.Latest firmware plus BNSF-40425 for 9.4.017+, or BNSF-40430 for older firmware.
Load Balancer ADC (CVE-2026-111560)Appliances missing the patch; this command injection requires administrative access on its own.Latest firmware plus BNADC-16586.
Message Archiver (CVE-2026-111560)Appliances missing the patch; this command injection requires administrative access on its own.Latest firmware plus BNMA-32468.
WAF Control Center (CVE-2026-111560)Appliances missing the patch; this command injection requires administrative access on its own.Latest firmware plus BNWF-60060.
Web Application Firewall (CVE-2026-111560)Appliances missing the patch; this command injection requires administrative access on its own.Latest firmware plus BNADC-16586.
Web Security Gateway (CVE-2026-111560)Appliances missing the patch; this command injection requires administrative access on its own.Latest firmware plus BNYF-24789.

Usá las indicaciones para tu producto y rama. Confirmá con el proveedor las correcciones adaptadas a tu distribución; el nombre del producto por sí solo no establece exposición.

¿Qué se sabe de la explotación?

Ataques observados

Ataques confirmadosCISA KEV · 2

Fundamento de la prioridad

Barracuda confirms exploitation and CISA lists both CVEs in KEV. Reachable ESG administration interfaces are the immediate concern; other products have separate prerequisites.

¿Qué implica para los entornos de IA?

Oktsec recommends reviewing credentials and integrations reachable from a compromised appliance. These flaws are not specific to AI.

Fuentes de este aviso

Abrir evidencia de respaldo y registro técnico
Historial editorial1 entrada

Added affected configurations, vendor corrections and confirmed exploitation evidence.

Acciones de respuesta

Prepará tu respuesta

0 de 3 acciones registradas como completadas

Usá esta lista para evaluar si el aviso afecta a tus sistemas, registrar las acciones de tu equipo y compartir el resultado. Radar no escanea ni verifica tu entorno.

Los cambios se guardan automáticamente en este navegador. No se sincronizan con tu equipo ni se envían a Oktsec.

1. Evaluá si aplica a tu entorno

Revisá los sistemas y versiones afectados y registrá tu decisión a continuación. Si tenés dudas, elegí «Requiere verificación».

Evaluación de aplicabilidadSin evaluar

2. Registrá la respuesta

Indicá el sistema y la persona o equipo responsable. Actualizá cada acción y agregá una referencia al ticket o notas sobre lo revisado.

  1. Identify product and management exposure

    Record the exact appliance, firmware, patch status and networks that could reach its administrative interface.

    Agregar evidencia o notasUsá solo referencias. No guardes credenciales ni datos confidenciales acá.
  2. Verify firmware and security patches

    Use the vendor table for the exact product. If a patch did not apply automatically, install it manually and verify completion.

    Agregar evidencia o notasUsá solo referencias. No guardes credenciales ni datos confidenciales acá.
  3. Investigate earlier access

    Oktsec recommends preserving logs, checking unexpected administrative changes and involving incident response if compromise is suspected. Patching alone does not prove removal of persistence.

    Agregar evidencia o notasUsá solo referencias. No guardes credenciales ni datos confidenciales acá.

3. Compartí el plan

Descargá un archivo Markdown con tu decisión, los estados de las acciones, las notas y las fuentes. Compartilo con tu equipo o adjuntalo a un ticket.

VERIFICÁ TU ENTORNO

Sistemas afectados y correcciones

Abrir plan de respuesta

Compará la versión en ejecución y la configuración con las indicaciones del proveedor.

ProductoAfectadoVersión corregida / acción
Email Security Gateway (both CVEs)Appliances missing the applicable security patch; administration UI must be reachable.Latest firmware plus BNSF-40425 for 9.4.017+, or BNSF-40430 for older firmware.
Load Balancer ADC (CVE-2026-111560)Appliances missing the patch; this command injection requires administrative access on its own.Latest firmware plus BNADC-16586.
Message Archiver (CVE-2026-111560)Appliances missing the patch; this command injection requires administrative access on its own.Latest firmware plus BNMA-32468.
WAF Control Center (CVE-2026-111560)Appliances missing the patch; this command injection requires administrative access on its own.Latest firmware plus BNWF-60060.
Web Application Firewall (CVE-2026-111560)Appliances missing the patch; this command injection requires administrative access on its own.Latest firmware plus BNADC-16586.
Web Security Gateway (CVE-2026-111560)Appliances missing the patch; this command injection requires administrative access on its own.Latest firmware plus BNYF-24789.

Confirmá con el proveedor las correcciones adaptadas a tu distribución. Coincidir en el producto no basta para establecer exposición.

Acceso necesarioDepende de la aplicación o configuración
EVIDENCIA CON FUENTES

Evidencia y fuentes

Revisado 11 nov 2026 UTC

Por qué tiene esta prioridad

Barracuda confirms exploitation and CISA lists both CVEs in KEV. Reachable ESG administration interfaces are the immediate concern; other products have separate prerequisites.

Criterios de prioridad

Evidencia de CISA KEV

Catálogo 2026.11.10 · Revisado 11 nov 2026 UTC

CISA incluye estos CVE en su catálogo de vulnerabilidades explotadas conocidas. Esto confirma explotación conocida, no el compromiso de tu entorno.

CVE-2026-116606Agregado 10 nov 2026
Uso en ransomware
No confirmado por CISA
Evaluación forense federal
Exigida por las indicaciones de CISA
Fecha límite federal
13 nov 2026

Acción indicada por CISA

Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

CVE-2026-111560Agregado 10 nov 2026
Uso en ransomware
No confirmado por CISA
Evaluación forense federal
Exigida por las indicaciones de CISA
Fecha límite federal
13 nov 2026

Acción indicada por CISA

Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.

Los plazos y requisitos federales de CISA se muestran como contexto. No son obligaciones universales para empresas privadas o de América Latina. La fecha de incorporación corresponde al catálogo, no al primer ataque.

Evidencia de respaldo

Producto / CVEEvidencia de ataquesIndicaciones de la fuente
Email Security GatewayCVE-2026-116606Ataques confirmados

Confirmado por CISA, la agencia de ciberseguridad de EE. UU.

Barracuda fuenteRevisar sistemas afectados
Email Security Gateway / Load Balancer ADC / Message Archiver / WAF Control Center / Web Application Firewall / Web Security GatewayCVE-2026-111560Ataques confirmados

Confirmado por CISA, la agencia de ciberseguridad de EE. UU.

Barracuda fuenteRevisar sistemas afectados
Estimaciones por CVE2 CVEs
CVE-2026-116606

1.6% de probabilidad estimada de explotación en los próximos 30 días. No es la probabilidad de un ataque a tu organización.

Puntaje del 10 nov 2026 · Superior al 76.03% de las vulnerabilidades evaluadas.Sin cambios desde 9 nov 2026.Datos de FIRST EPSS
CVE-2026-111560

1.06% de probabilidad estimada de explotación en los próximos 30 días. No es la probabilidad de un ataque a tu organización.

Puntaje del 10 nov 2026 · Superior al 64.83% de las vulnerabilidades evaluadas.Sin cambios desde 9 nov 2026.Datos de FIRST EPSS

FIRST EPSS · Revisado 2026-11-11 13:38 UTC

La prioridad corresponde al aviso, no a cada producto o CVE por separado. Cada fila muestra solo la evidencia atribuida a ese CVE. La falta de evidencia de ataques no permite descartar una vulnerabilidad. Tu entorno no fue escaneado.

Fuentes

Los datos técnicos provienen de estas fuentes. Las prioridades y las acciones recomendadas son el análisis de Oktsec.

  1. Barracuda: security advisoryBarracuda · Aviso del proveedor · Revisado 11 nov 2026 UTC
  2. CISA KEV: exact CVE recordsCISA · Aviso gubernamental · Revisado 11 nov 2026 UTC
Registro técnicoProductos, identificadores y detalles de respaldo
Registro del incidente
Producto / servicioEmail Security Gateway, Load Balancer ADC, Message Archiver, WAF Control Center, Web Application Firewall, Web Security GatewayBarracuda
CVECVE-2026-116606CVE-2026-111560
Evidencia de explotación
Ataques confirmadosCISA KEV · 2
Acceso necesarioDepende de la aplicación o configuración
Corrección / respuesta
Divulgado
2 nov 2026
Registro revisado
11 nov 2026 UTC

Para entornos con agentes de IA

Oktsec recommends reviewing credentials and integrations reachable from a compromised appliance. These flaws are not specific to AI.